Fike twinflex fire alarm system range the safety centre. Hello have few questions first can i even do this i am looking to install a fike twinflex pro fire alarm system in my home i have gotten the ok from my housing association to do this but am i allowed to do this by law i have been looking into it and have seen most systems need design plans. Oftentimes, the issue is solved with simple troubleshooting. Twinflex pro osp is the name given to the high level software package written to enable the individual configuration of the twinflex pro fire alarm systems. Twinflexpro osp software is only operational in engineer level, details of which are given in the twinflexpro engineer and commissioning manual. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability. It is nice a simple but firstly you need the correct test key and user key and. Making it a simple, innovative and cost effective fire alarm system. And our newest product, 3m tm novec tm 1230 fire protection fluid is the worlds most environmentally friendly chemical clean agent. From engineering solutions to help solve the bp oil spill to protecting a museums irreplaceable artifacts from fire, fike s industrial from engineering solutions to help solve the bp oil spill to protecting a museums irreplaceable artifacts from fire, fike s industrial safety solutions can vary greatly. The electrical compliance lab is equipped with one of every electrical product offered by fike. We sometimes fit these, the software part has always been optional to speed up installation. This type of system uses traditional zone circuits, but allows detectors, manual.
Fike offers a complete selection of fire suppression solutions, from chemical agents and water mist to inert gases and co2. Twinflex pro control panel engineering and commissioning manual 2 fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. To eliminate catastrophic loss of life and assets for companies around the world. Control panel engineering and commissioning manual fire and.
No related manuals summary of contents for fike twinflex pro 2. Fike twinflex pro 2 quick start manual pdf download. The devices communicate with the control panel using the twinflex data protocol. The twinflex pro system is an intelligent 2wire system utilising a conventional type cabling format. Control panel engineering and commissioning manual finding zone faults a fault on a zone of the twinflexpro. Twinflex v3 control panel user guide 7 the standard specifies a number of maintenance tasks which include a visual inspection of the installation to ensure that there are no alterations or obstructions which could affect the operation of the system, and functional checks to confirm the operation of the system. Here is the threading code i would use for my ospp200l. Twinflex, mulitpoint, fike and fike corporation are registered trademarks of fike. And i didnt need a laptop to commission, ive just finshed it all and ready to commission but the manual says i need a laptop with file software is this right i dont really want to do another. Welcome to the sd fire alarms fike twinflex pro panel description part 4 video. Buy fike twinflex pro fire alarm control panels, sounders, detectors and spares from stock at low trade prices, with quick shipping at. Ensure that the control panel will be easily accessible and that account is taken of any subsequent work that may affect access. Fike twinflex pro2 engineering and commissioning manual 80 pages. Fike s innovative range of fire detection and warning systems are far more technologically advanced than those of other fire alarm companies.
Vision to eliminate catastrophic loss of life and assets for companies around the world. Single flood zone fire suppression system control panel. Fire protection detection and suppression solutions fike. This section should be completed by the commissioning engineer at handover. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of. Fike multipoint head removal tool, fire protection tools, 25 0015 fike twinflex multipoint head removal tool black.
Fike suppression systems are designed to detect and chemically suppress an explosion in its earliest stages before an explosion can cause a disaster or become catastrophic. The multipoint and asd detectors have set new standards in detector technology. View and download fike twinflex irm 011 engineering and commissioning manual online. In this video i show a demo on testing a fike twinflex pro manual call point on a fike twinflex pro. The system is classed as analogue nonaddressable due to the architecture used within the design. Explosions are no laughing matter when left undetected. In order to prove whether the fault is control panel based or in the field including the field wiring, swap the wires from the zone in fault with those in a clear zone active but no fault at the control panel. Repeater panel engineering and commissioning manual. Fike twinflex fire alarm systems are now available from discount fire supplies. Impulse releasing module, suitable for control panels from v01. Fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. Twinflex v3 control panel user guide 2 fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Fike twinflexpro2 2 zone boxed kit approved 6040002. Control panel engineering and commissioning instructions.
The instructions are written on the basis that the installer may be unfamiliar with the equipment, but assumes that they have an engineering background and are generally conversant with the requirements of bs 5839 part 1, or other. The twinflexpro2 panel is an intelligent 2wire panel that utilises a conventional type cabling format. Emc twinflex pro repeater panel engineering and commissioning manual this equipment when installed is subject to the emc directive 2004108ec. Twinflex is the name of the range of control panels and associated devices which together form the fire alarm system installed in the premises, and is derived from the method of wiring whereby trigger. Mere seconds can be the difference between a minor incident and a major disaster. Testing fike twinflex pro panel and mcp fire alarm demo duration. Electrical compliance factory acceptance testing fike. The twinflex multipoint head is a 2wire device used with the twinflex and twinflex pro systems, whereas the addressable asd detector is used on the sita200plus, duonet and quadnet systems. Do not call the fike safety technology support department unless your distributor has first given their advice and attempted to rectify the issue.
Fike safety technology ltd unit 31 springvale industrial estate, cwmbran np44 5bd uk tel. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. If a client identifies a problem, fike s technical support can load the clients version of software into the device and attempt to recreate the issue. Welcome to the sd fire alarms fike twinflex pro panel description part 2 video. View and download fike twinflex pro2 engineering and commissioning manual. Their comprehensive range includes intelligent smokeheat detectors, sounders, manual call points and control panels. Download fike twinflex pro2 engineering and commissioning.
The the system is classed as analogue nonaddressable due to the architecture used within the design. This time, we have the pleasure to collaborate with one of our main manufacturers. Fike s comprehensive fire detection solutions range from the latest in fire alarm panel technology, air sampling detectors and nearly everything in between. The codes may be changed using the relevant panel menu or via the twinflex pro osp software. Control panel user guide fire and electrical safety ltd. The twinflexpro two wire fire alarm system incorporating the multipoint asd combined smoke and heat detector with optional builtin sounder and strobe, allows the whole system to be easily installed using only one pair of wires per zone. Fike united kingdom 35 earl street, maidstone, kent me14 1pf uk tel. Twinflex fire alarm systems are installed using only one pair of wires and two types of devices twinflex multipoint detectors with optional sounder and twinflex manual callpoints. Control panel fike twinflex srp 001 engineering and commissioning manual 78 pages.
The fike twinflex range is a range of two wire type fire alarm system equipment. Teaming up with engineers that have studied and can denote explosions fike has become number one in the industry. In this video i show a demo on testing a fike twinflex pro manual call point on a fike twinflex pro fire alarm panel. Control panel fike twinflexpro user manual 15 pages.